Skip to main content

Reply to "thermostat by pass has frost plug in. i need both sides of this argument please."

Chris,

The Cleveland was originally designed to use the brass restrictor plate WITHOUT the frost plug, a water pump WITH a bypass passage, AND a CLEVELAND SPECIFIC thermostat.

Others have modified the original Cleveland design by adding a frost plug to the brass restrictor plate (as you have in yours), using a water pump WITHOUT a bypass passage, and using ANY thermostat.

John
×
×
×
×